Back to Top

1
Hi, Guest!

  LOKASI :  Jakarta Pusat

  AKTIVITAS :  18/03/2020

BAGIKAN :   

Bagikan :
Masukan Data Diri Anda
Nama harus diisi !
Email harus diisi !
Format email harus someone@example.com !
Kontak Kami  

PIPA CASING

Update Terakhir
:
08 / 12 / 2019
Min. Pembelian
:
0
Harga
CALL
Bagikan
:
PT.TRICON DOS SEJAHTERA STOCKIST, SUPPLIER & GENERAL CONTRACTOR Jl.Angkasa MGK ( Mega Glodok Kemayoran ) LT.1,Blok.C11 No.19- 20 Telp : ( 021 ) 29070800 Fax : ( 021 ) 29070799 Email:triconsejahtera@gmail.com Dengan hormat, Bersama ini kami ingin memperkenalkan perusahaan kami PT.TRICON DOS SEJAHTERA ( TDS ) sebagai stockies dan distributor

Detail JUAL PIPA CASING

PIPA CASING : Casing pipes crossing under roadways/ railroads shall be located at suitable approved alignments in order to eliminate possible conflicts with existing or future utilities and structures, with a minimum 36-inch depth of cover between the top of the casing pipe and the surface of the roadway. Casing length shall extend a minimum of eight feet beyond the edge of pavement or curbing. Casings shall be pipe conforming to the requirements of ASTM Designation A-139. Carrier shall be Ductile Iron Pipe Class 250, HDPE C-905 or PVC C-900. The minimum casing pipe size and wall thickness shall be as shown in the following table for the water or wastewater carrier pipe size indicated. For sizes not included therein, or for special design considerations, approval shall be obtained from the Utilities Casing Pipe Size & Wall Thickness SIZE INCH THICKNESS INCH 12 " x Thickness 5/ 16 " 18 " x Thickness 5/ 16 " 20 " x Thickness 5/ 16 24 " x Thickness 3/ 8 " 24 " x Thickness 3/ 8 " 30 " x Thickness 1/ 2 " 42 " x Thickness 1/ 2 " 48 " x Thickness 1/ 2 " 54 " x Thickness 5/ 8 " 60 " x Thickness 5/ 8 " 66 " x Thickness 5/ 8 "
Tampilkan Lebih Banyak
pt.tricon dos sejahtera
pt.tricon dos sejahtera

PT.TRICON DOS SEJAHTERA

PREMIUM GOLD 5 Tahun
Jln.Angkasa,Gedung MGK ( Mega Glodok Kemayoran ) Lt.1 Blok : C11- No.19-20, Jakarta Pusat
Indonesia 10610
Jakarta Pusat
18 / 03 / 2020
Hubungi Kami

Detail JUAL PIPA CASING

PIPA CASING : Casing pipes crossing under roadways/ railroads shall be located at suitable approved alignments in order to eliminate possible conflicts with existing or future utilities and structures, with a minimum 36-inch depth of cover between the top of the casing pipe and the surface of the roadway. Casing length shall extend a minimum of eight feet beyond the edge of pavement or curbing. Casings shall be pipe conforming to the requirements of ASTM Designation A-139. Carrier shall be Ductile Iron Pipe Class 250, HDPE C-905 or PVC C-900. The minimum casing pipe size and wall thickness shall be as shown in the following table for the water or wastewater carrier pipe size indicated. For sizes not included therein, or for special design considerations, approval shall be obtained from the Utilities Casing Pipe Size & Wall Thickness SIZE INCH THICKNESS INCH 12 " x Thickness 5/ 16 " 18 " x Thickness 5/ 16 " 20 " x Thickness 5/ 16 24 " x Thickness 3/ 8 " 24 " x Thickness 3/ 8 " 30 " x Thickness 1/ 2 " 42 " x Thickness 1/ 2 " 48 " x Thickness 1/ 2 " 54 " x Thickness 5/ 8 " 60 " x Thickness 5/ 8 " 66 " x Thickness 5/ 8 "
Tampilkan Lebih Banyak